Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Hubei, Peoples R China [2]Siemens Healthcare, MR Collaborat, Shenzhen 518000, Peoples R China [3]Siemens Healthcare, MR Sci Mkt, Wuhan 430030, Hubei, Peoples R China [4]Siemens Shenzhen Magnet Resonance, Shenzhen 518000, Peoples R China
出处:
ISSN:

关键词: Echo planar imaging Breast neoplasms Signal-to-noise ratio

摘要:
Objectives To investigate the feasibility and effectiveness of SMS rs-EPI for evaluating breast lesions. Methods This prospective study was approved by IRB. Ninety-six patients had 102 histopathologically verified lesions (80 malignant and 22 benign) that were evaluated. Conventional rs-EPI and SMS rs-EPI data were acquired on a 3T scanner. Mean kurtosis (MK), mean diffusion (MD), and apparent diffusion coefficient (ADC) values were quantitatively calculated for each lesion on both sequences. Images were qualitatively and quantitatively analyzed with respect to image sharpness, geometric distortion, lesion conspicuity, anatomic structure, overall image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Student's t test, Pearson correlation, receiver operating characteristic curve, Wilcoxon rank sum test, and paired-sample t tests were used for statistical analysis. Results Compared to conventional rs-EPI, the acquisition time of SMS rs-EPI was markedly reduced (2:17 min vs 4:27 min). Pearson's correlations showed excellent linear relationships for each parameter between conventional rs-EPI and SMS rs-EPI (MK, r = 0.908; MD, r = 0.938; and ADC, r = 0.975; p < 0.01 for all). Furthermore, SMS rs-EPI had similar diagnostic performance compared with conventional rs-EPI. SMS rs-EPI had comparable visual image quality as conventional rs-EPI, with excellent inter-reader reliability (ICC = 0.851-0.940). No differences existed between conventional rs-EPI and SMS rs-EPI for either SNR or CNR (p > 0.05). Conclusions Applying the SMS technique can significantly reduce the acquisition time and produce similar diagnostic accuracy while generating comparable image quality as the conventional rs-EPI. Key Points SMS rs-EPI reduces scan time from 4:27 min to 2:17 min compared with conventional rs-EPI. SMS rs-EPI has a comparable diagnostic performance to conventional rs-EPI in the differentiation between malignant and benign breast lesions. SMS rs-EPI demonstrates comparable image quality to conventional rs-EPI with shorter scan time.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2019]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)