高级检索
当前位置: 首页 > 详情页

Feasibility Study of 3-T DWI of the Prostate: Readout-Segmented Versus Single-Shot Echo-Planar Imaging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Radiol,Wuhan 430030,Hubei,Peoples R China [2]MR Collaborat NE Asia, Siemens Healthcare, Shanghai, Peoples R China [3]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Urol,Wuhan 430030,Hubei,Peoples R China
出处:
ISSN:

关键词: diffusion-weighted imaging echo-planar imaging MRI prostate readout-segmented echo-planar imaging

摘要:
OBJECTIVE. The purpose of this prospective study was to assess the clinical utility of generalized autocalibrating partial parallel acquisition (GRAPPA)-accelerated readout-segmented echo-planar imaging (rs-EPI) DWI and compare it with standard single-shot EPI (-ss-EPI) DWI in visualization of the prostate during 3-T MRI. SUBJECTS AND METHODS. One hundred sixteen consecutively registered patients (mean age, 63.5 years; range 24-93 years) underwent 3-T MRI that included rs-EPI DWI and standard ss-EPI DWI with identical FOVs, slices, acceleration factors, b values, and image postprocessing procedure. The datasets were independently evaluated by two blinded radiologists. Images were evaluated for sharpness, anatomic distortion, imaging contrast, lesion conspicuity, detailed anatomic visualization, and overall image quality on a 5-point Likert scale (1, nondiagnostic; 5, excellent). RESULTS. The kappa values were 0.73 for image sharpness, 0.71 for anatomic distortion, 0.54 for imaging contrast, 0.56 for lesion conspicuity, 0.61 for detailed anatomic visualization, and 0.63 for overall image quality (all p < 0.05), indicating moderate to substantial agreement between the two observers. The mean Likert scores for standard ss-EPI and -rs-EPI were as follows: image sharpness, 2.9 and 4.6; distortion level, 2.8 and 4.4; contrast, 3.1 and 3.8; lesion conspicuity, 3.0 and 4.0; structure, 3.1 and 4.2; and overall image quality, 3.1 and 4.2. The rs-EPI DWI sequence was associated with significantly better image quality and fewer susceptibility artifacts than was ss-EPI (all p < 0.05). The rs-EPI sequence was considered better overall in 90% of cases. CONCLUSION. The technique of rs-EPI DWI combined with GRAPPA enables robust prostate imaging with high image quality and may provide great benefit in routine clinical practice.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2013]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Radiol,Wuhan 430030,Hubei,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)