高级检索
当前位置: 首页 > 详情页

Three-dimensional SPACE MR with CAIPIRINHA fourfold acceleration for assessing long head of biceps tendon

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Jianghan Univ, Dept Radiol, Hubei 3 Peoples Hosp, Wuhan, Peoples R China [2]Huazhong Univ Sci & Technol, Dept Radiol, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
出处:
ISSN:

关键词: CAIPIRINHA long head of biceps tendon 3D MR acceleration SPACE

摘要:
Background Data regarding controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) T2-weighted sampling perfection with application optimized contrast evolution (SPACE) with fourfold acceleration factor for assessing long head of biceps tendon (LHBT) disorder is lacking. Purpose To investigate the feasibility of 3D CAIPIRINHA SPACE with fourfold acceleration in assessing LHBT disorder. Material and Methods A total of 42 consecutive patients underwent shoulder magnetic resonance (MR) examinations including CAIPIRINHA SPACE with fourfold acceleration, and non-CAIPIRINHA SPACE with twofold acceleration, and 2D fast spin echo (FSE). A subjective score of depiction of LHBT was given to 3D sequence according to a 4-point scale (0-3, "poor" to "excellent"). The Wilcoxon signed rank test was used to compare depiction scores between 3D sequences. Three statuses of LHBT were defined in the study: normal, tendonitis, and tear. McNemar's test was used compare diagnostic accuracy. Results LHBT was better depicted with CAIPIRINHA SPACE versus non-CAIPIRINHA SPACE (2.1 +/- 0.4 vs. 1.5 +/- 0.4; P < 0.001). Inter-modality agreement between CAIPIRINHA SPACE and 2D FSE was almost perfect (kappa = 0.884 +/- 0.064). The sensitivity and specificity in detecting LHBT disorder were 95% (20/21) and 95% (20/21), respectively, for CAIPIRINHA SPACE, and 71% (15/21) and 76% (16/21), respectively, for non-CAIPIRINHA SPACE (P = 0.039). Conclusion Fourfold acceleration CAIPIRINHA is feasible in reducing the acquisition time of SPACE MR in the shoulder. 3D CAIPIRINHA SPACE with fourfold acceleration is highly accurate in detecting LHBT disorder.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2021]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Jianghan Univ, Dept Radiol, Hubei 3 Peoples Hosp, Wuhan, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)