Imaging of the Silicone Implant with a 3D SPACE MR Sequence: The Accuracy for Estimating Implant Volume and Reconstructing Implant Deformation in Breast Surgery

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Dept Plast Surg, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China [2]Huazhong Univ Sci & Technol, Dept Radiol, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
出处:
ISSN:

摘要:
Objective The study is to assess the accuracy and reliability of 3D simulated magnetic resonance imaging with SPACE sequence for estimating implant volume and reconstructing implant deformation, which may assist in the diagnosis of implant complications and making individualized surgical plans for these patients. Methods MRI examinations of ten silicone implants were performed with T2, H2O-excitation SPACE sequence (T2-spc-H2O) and silicone-excitation SPACE sequence (T2-spc-Silicone) to find the most accurate method to estimate implant volume by ITK-SNAP. The effect of implant deformation and voxel size of silicone-excitation SPACE sequence on volume measurement was investigated. Thirteen normal patients and ten patients with implant complications (Wuhan Tongji Hospital from March 2017 to May 2019) were enrolled for testing the accuracy and reliability of 3D simulated MRI with silicone-excitation SPACE sequences for volume measurement and reconstructing implant deformation in patients. Results The absolute volume differences of T2-spc-Silicone group were significantly less than T2-spc-H2O and T2 group (6.28 vs. 23.27 vs. 42.19 mL, P < 0.05) in vitro. No significant difference was found between the normality group and the deformation group for estimating the volume of implants. Besides, the voxel size of T2-spc-Silicone from 0.5 x 0.5 x 0.5 mm to 5.0 x 5.0 x 5.0 mm did not significantly affect the accuracy of volume measurement of the implants in deformation state. However, 3D images of the implant became blurred with the voxel size increased. With the voxel size larger than 1.5 x 1.5 x 1.5 mm, the scores of image quality decreased significantly. The number of folds could not be identified accurately with the voxel size larger than 2.0 x 2.0 x 2.0 mm. In normal patients, the measurement errors of T2-spc-Silicone were around 10 mL. In the patients with implant complications, there was no significant difference between measured volume and the actual volume of implants. Moreover, implant deformations were clearly presented by T2-spc-Silicone with the voxel size of 1.0 x 1.0 x 1.0 mm. The results showed excellent intraobserver reliability (ICC = 0.997 > 0.8), and internal consistency ranged from 0.986 to 0.997 (P < 0.001). Conclusions The method to measure implant volume by 3D simulated magnetic resonance imaging with T2-spc-Silicone sequence had possessed desirable accuracy and reliability. The deformation of the implant and the voxel size of the T2-spc-Silicone sequence didn't exhibit a significant effect on the accuracy of the measurement. T2-spc-Silicone with voxel size less than 2.0 x 2.0 x 2.0 mm could be used for 3D reconstruction of the implant deformation. The 1.0 x 1.0 x 1.0 mm was a suitable voxel size to reconstruct implant deformation clearly and quickly.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 外科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 外科
JCR分区:
出版当年[2019]版:
Q3 SURGERY
最新[2023]版:
Q2 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Dept Plast Surg, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)