A quantitative grading system of vesicoureteral reflux by contrast-enhanced voiding urosonography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, 1095 Jiefang Ave, Wuhan 430030, Hubei, Peoples R China [2]Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA [3]Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL USA [4]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Paediat, Tongji Med Coll, Wuhan, Peoples R China
出处:
ISSN:

关键词: contrast-enhanced voiding urosonography vesicoureteral reflux quantitative grading system cut-off value

摘要:
Aims: Contrast-enhanced voiding urosonography (ceVUS) is a well-established imaging modality for the diagnosis of vesicoureteral reflux (VUR). However, discrepancies of grading diagnosis of VUR exist due to the qualitative aradina criteria currently used in clinics. This study aimed to evaluate numerical markers for a quantitative VUR grading system. Material and methods: CeVUS images of grade II-VVUR were analysed. A quantitative indicator, i.e. sectional area ratio (SAR), on the imaging section with maximum cross-section area and the presence of kidney hilum was calculated to distinguish different grades of VUR. The diagnostic performance of SAR was evaluated using receiver operating characteristic curve (ROC) analysis, and the maximiun Youden Index was used to determine the optimal cut-off values. Results: A total of 63 patients with 126 Pelvillreteral Units were enrolled. The SAR value increased significantly along with the increase of VUR grade. SAR had an excellent diagnostic performance in grading VUR. For differentiating VUR of grade II vs III, III vs IV and IV vs V, the area under the ROC curve values of SAR were 0.967, 0.943 and 0.865, respectively, while the optimal SAR cut-off values were 14.3%. 34.9% and 51.0%, respectively. The quantitative grading system based on the optimal SAR cut-off values showed excellent consistency with the qualitative grading system of VUR currently used in clinic. Conclusions: The numerical indicator SAR calculated from ceVUS may be used to establish a quantitative VUR grading system with excellent diagnostic performance and can potentially serve as a reliable tool for the evaluation and follow-up of VUR.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
JCR分区:
出版当年[2018]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, 1095 Jiefang Ave, Wuhan 430030, Hubei, Peoples R China [2]Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA [3]Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL USA
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, 1095 Jiefang Ave, Wuhan 430030, Hubei, Peoples R China [2]Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA [3]Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)