Evaluation of Scoliosis With a Commercially Available Ultrasound System

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Huazhong Univ Sci & Technol, Dept Med Ultrasound, Tongji Hosp, Tongji Med Coll, 1095 Jiefang Rd, Wuhan 430030, Peoples R China [2]Huazhong Univ Sci & Technol, Dept Rehabil Med, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
出处:
ISSN:

关键词: Cobb angle coronal curvature reliability scoliosis 3-dimensional ultrasound

摘要:
Objectives-Currently, radiography with measurement of the Cobb angle is still considered the reference standard for diagnosing scoliosis. However, the ionizing radiation hazard is drawing wide attention. Can 3-dimensional (3D) ultrasound (US) be an alternative modality for diagnosing and monitoring patients with scoliosis? The aim of our study was to assess the reliability and validity of 3D US imaging in the evaluation of scoliosis. Methods-A commercially available ultrasound system with a magnetic tracking system was selected for long-distance 3D US imaging. Straight phantoms and curved phantoms were scanned with the imaging system to evaluate the stability of the system for curvature measurements. Eight healthy adult volunteers and 28 patients with scoliosis were recruited for long-distance 3D US imaging. The intraclass correlation coefficient was used to test the reproducibility of the interobserver and intraobserver measurements for both the healthy adults and patients with scoliosis. A linear regression analysis and Bland-Altman plot were used to analyze the correlation and to determine the extent of agreement between the angles measured on US images and the Cobb angles measured on conventional radiographs. Results-The 28 patients with scoliosis included 10 male and 18 female patients aged 8 to 37 years (mean age +/- SD, 17.7 +/- 1.4 years; body mass index, <25 kg/m(2)). In the phantom study, there was no statistically significant difference between the angles measured by the 3D US imaging system and those measured by an angle gauge (P > 0.05). In the clinical study, there was very good interobserver and intraobserver reliability (intraclass correlation coefficients, >0.90) for the US imaging system, with a high correlation (r(2) = 0.92) and agreement between the US and radiographic methods. Conclusions-The long-distance 3D US imaging system offers a viable modality for diagnosing and monitoring scoliosis without radiation.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2018]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Dept Med Ultrasound, Tongji Hosp, Tongji Med Coll, 1095 Jiefang Rd, Wuhan 430030, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)