Development and Evaluation of a Portable MVT-Based All-Digital Helmet PET Scanner

| 导出 | |

文献详情

资源类型:
WOS体系:

收录情况: ◇ ESCI

单位: [1]Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China [2]Univ Sci & Technol China, Dept Elect Engn & Informat Sci, Hefei 230026, Peoples R China [3]Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Med Phys & Engn, I-86077 Pozzilli, Italy [4]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Neurol,Wuhan 430074,Peoples R China [5]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Nucl Med,Wuhan 430074,Peoples R China [6]Shenzhen Univ, Coll Life Sci & Oceanog, Shenzhen 518055, Peoples R China [7]Sapienza Univ Rome, Dept Clin Internal Med Anesthesiol & Cardiovasc Sc, I-00185 Rome, Italy [8]Otto von Guericke Univ, Univ Hosp Magdeburg, Dept Radiol & Nucl Med, D-39106 Magdeburg, Germany [9]Univ Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 611731, Peoples R China [10]Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
出处:
ISSN:

关键词: Advanced diagnostics helmet brain positron emission tomography hemispherical detector arrangement multi voltage threshold (MVT) portable positron emission tomography

摘要:
Novel design solutions for dedicated portable brain positron emission tomography systems with improved performance facilitate emergency and interventional image-guided surgery as well as advanced diagnostics of clinically impaired patients with neurodegenerative diseases. We report a novel portable MVT-based All-Digital helmet PET system with a hemispherical detector arrangement based on the Multi Voltage Threshold technology. It has a transverse and axial field of view (FOV) of 200 and 124 mm, respectively. It allows to scan subjects in a standing, sitting, and lying position. We evaluated the performance of the system according to NEMA standards. The scanner exhibits a noise equivalent count rate peak of (151 +/- 2) kcps at the activity of 40.65 kBq/mL, a sensitivity of (55.24 +/- 0.05) cps/kBq, and a spatial resolution at the center of the FOV of approximately 3.3 mm (FWHM), when using the filtered back projection algorithm. For a mini Derenzo phantom, rods of 2.0-mm diameter can be clearly separated. Time-dynamic ( )[F-18 ]-Fluorodeoxyglucose human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 30 s time frames. We finally verified the usability of the device in the diagnostics of Alzheimer's Disease by imaging human subjects with [F-18 ]-Florbetapir.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2023]版:
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2022]版:
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China [2]Univ Sci & Technol China, Dept Elect Engn & Informat Sci, Hefei 230026, Peoples R China [3]Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Med Phys & Engn, I-86077 Pozzilli, Italy [10]Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)