Automatic and continuous blood pressure monitoring via an optical-fiber-sensor-assisted smartwatch

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Natl Engn Res Ctr Next Generat Internet Access Sys, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Div Cardiol,Hubei Key Lab Genet & Mol Mech Cardiol, Wuhan 430074, Peoples R China [3]Huawei Technol Co Lt, Shenzhen 218129, Peoples R China [4]Huazhong Univ Sci & Technol, HUST Wuxi Res Inst, Wuxi 214174, Peoples R China [5]Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China
出处:

关键词: Blood pressure Optical fiber sensor Smartwatch

摘要:
Automatic and continuous blood pressure monitoring is important for preventing cardiovascular diseases such as hypertension. The evaluation of medication effects and the diagnosis of clinical hypertension can both benefit from continuous monitoring. The current generation of wearable blood pressure monitors frequently encounters limitations with inadequate portability, electrical safety, limited accuracy, and precise position alignment. Here, we present an optical fiber sensor-assisted smartwatch for precise continuous blood pressure monitoring. A fiber adapter and a liquid capsule were used in the building of the blood pressure smartwatch based on an optical fiber sensor. The fiber adapter was used to detect the pulse wave signals, and the liquid capsule was used to expand the sensing area as well as the conformability to the body. The sensor holds a sensitivity of -213 & mu;w/kPa, a response time of 5 ms, and high reproducibility with 70,000 cycles. With the assistance of pulse wave signal feature extraction and a machine learning algorithm, the smartwatch can continuously and precisely monitor blood pressure. A wearable smartwatch featuring a signal processing chip, a Bluetooth transmission module, and a specially designed cellphone APP was also created for active health management. The performance in comparison with commercial sphygmomanometer reference measurements shows that the systolic pressure and diastolic pressure errors are -0.35 & PLUSMN; 4.68 mmHg and -2.54 & PLUSMN; 4.07 mmHg, respectively. These values are within the acceptable ranges for Grade A according to the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). The smartwatch assisted with an optical fiber is expected to offer a practical paradigm in digital health.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 1 区 物理与天体物理
小类 | 1 区 光学
最新[2025]版:
大类 | 1 区 物理与天体物理
小类 | 1 区 光学
JCR分区:
出版当年[2021]版:
Q1 OPTICS
最新[2024]版:
Q1 OPTICS

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Natl Engn Res Ctr Next Generat Internet Access Sys, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Natl Engn Res Ctr Next Generat Internet Access Sys, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China [4]Huazhong Univ Sci & Technol, HUST Wuxi Res Inst, Wuxi 214174, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)