资源类型:
期刊
WOS体系:
Article
Pubmed体系:
Journal Article
收录情况:
◇ SCIE
文章类型:
论著
单位:
[1]Nursing Department,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,No. 1095,Jiefang Avenue,Wuhan 430000,Hubei Province,China.
华中科技大学同济医学院附属同济医院
护理部
ISSN:
1471-2261
关键词:
Cardiogenic shock
Coronary care unit
Invasive central aortic pressure
Invasive peripheral arterial pressure
Intra-aortic balloon pump
摘要:
Hemodynamic monitoring is imperative for patients with cardiogenic shock undergoing Intra-aortic Balloon Pump (IABP) therapy. Blood pressure monitoring encompasses non-invasive, invasive peripheral arterial pressure (IPAP), and invasive central aortic pressure (ICAP) methods. However, marked disparities exist between IPAP and ICAP. This study examined the discrepancies between IPAP and ICAP and their clinical significance.A retrospective analysis was conducted on cardiogenic shock patients who underwent IABP therapy and were admitted to the Coronary Care Unit (CCU) of a tertiary hospital in China from March 2017 to November 2022. The Bland-Altman plot illustrated the discrepancy between IPAP and ICAP. A clinically significant difference between ICAP and IPAP measurements was defined as ≥ 10 mmHg, which could necessitate alterations in blood pressure management according to current guidelines that recommend maintaining a mean arterial pressure (MAP) ≥ 70 mmHg.In total, 162 patients were included in the final analysis. In patients without vasopressors, the difference between ICAP and IPAP was 5.73 mmHg (95% limits of agreement [LOA], -16.98 to 28.44), whereas, in patients with vasopressors, it was 4.36 mmHg (95% LOA, -17.31 to 26.03). ICAP measurements exceeded IPAP in patients undergoing IABP therapy. However, the difference was not statistically significant between the two groups. Multivariate logistic regression revealed that higher serum lactate levels (Odds ratio [OR], 1.14; 95% confidence interval [CI], 1.03-1.27; p = 0.013) and age ≥ 60 years (OR, 13.20; 95% CI, 1.50-115.51; p = 0.020) were associated with an increased likelihood of a clinically significant MAP discrepancy. Conversely, a history of coronary heart disease was associated with a decreased likelihood (OR, 0.34; 95% CI, 0.13-0.90; p = 0.031).Notable discrepancies between ICAP and IPAP measurements exist in cardiogenic shock patients undergoing IABP therapy. ICAP exceeds IPAP, and factors such as age ≥ 60 years, elevated lactic acid levels, and absence of coronary heart disease contribute to this discrepancy. Enhanced vigilance is warranted for these patients, and the consideration of peripheral invasive monitoring in conjunction with IABP therapy is advised.© 2023. BioMed Central Ltd., part of Springer Nature.
基金:
This research did not receive any specifc grant from funding agencies in the
public, commercial, or not-for-proft sectors.
WOS:
WOS:001063767400002
PubmedID:
37689650
中科院(CAS)分区:
出版当年[2022]版:
大类
|
4 区
医学
小类
|
4 区
心脏和心血管系统
最新[2025]版:
大类
|
3 区
医学
小类
|
4 区
心脏和心血管系统
JCR分区:
出版当年[2021]版:
Q4
CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q3
CARDIAC & CARDIOVASCULAR SYSTEMS
影响因子:
2
最新[2023版]
2.3
最新五年平均
2.174
出版当年[2021版]
2.644
出版当年五年平均
2.298
出版前一年[2020版]
2.1
出版后一年[2022版]
第一作者:
Lu Lijuan
第一作者单位:
[1]Nursing Department,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,No. 1095,Jiefang Avenue,Wuhan 430000,Hubei Province,China.
共同第一作者:
Zhang Shiyi
推荐引用方式(GB/T 7714):
Lu Lijuan,Zhang Shiyi,Zhang Yu,et al.Discrepancy between two invasive blood pressure measurements in patients receiving intra-aortic balloon pump therapy[J].BMC CARDIOVASCULAR DISORDERS.2023,23(1):doi:10.1186/s12872-023-03479-2.
APA:
Lu Lijuan,Zhang Shiyi,Zhang Yu&Zhao Xiaoyan.(2023).Discrepancy between two invasive blood pressure measurements in patients receiving intra-aortic balloon pump therapy.BMC CARDIOVASCULAR DISORDERS,23,(1)
MLA:
Lu Lijuan,et al."Discrepancy between two invasive blood pressure measurements in patients receiving intra-aortic balloon pump therapy".BMC CARDIOVASCULAR DISORDERS 23..1(2023)