高级检索
当前位置: 首页 > 详情页

Accuracy and Challenges in the Vesical Imaging-Reporting and Data System for Staging Bladder Cancer.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei,China. [2]Department of Urology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei,China. [3]Russell H. Morgan Department of Radiology and Radiological Science, the Johns Hopkins Medical Institutions, Baltimore, Maryland, USA.
出处:
ISSN:

摘要:
The Vesical Imaging-Reporting and Data System (VI-RADS) scoring system has been widely used to stage bladder cancer (BCa) since 2018.To describe the characteristics of cases with discordant T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) scores in patients with BCa and further verify the accuracy of the VI-RADS scoring system and the necessity of dynamic contrast-enhanced (DCE) sequence.Retrospective.A total of 106 patients (include 16.5% female) with bladder cancer.T2WI (fast spin echo), DWI (echo planer imaging), and DCE (gradient echo).Some cases are difficult to score according to the system, mainly when the T2WI (category 4) and DWI (category 2) sequence scores are discordant, termed the discordant group below. The complementary group will be termed concordant group. Each MRI sequence was reviewed respectively according to the 5-point VI-RADS scoring system by three observers. The diagnostic ability of sequences for evaluating muscle invasion by BCa was calculated using histopathology as the reference standards.Receiver operating characteristic (ROC) curve, DeLong test, intraclass correlation coefficient. A P value of 0.05 or less was considered statistically significant.Fourteen cases (13.2%) had discordant VI-RADS scoring system. In the discordant group, the area under the ROC curve (AUC) of DCE was 0.875, while the T2WI and DWI showed limited diagnostic performance (AUCs = 0.50). In the concordant group, there was no significant difference in diagnostic efficacy between the overall VI-RADS (AUC: 0.950) and the combination of T2WI and DWI (AUC: 0.946) (P = 0.56). Among all patients, the AUC of overall VIRADS was 0.939 with a 3 or greater cutoff value.The DCE was crucial in the discordant group for evaluating muscle-invasiveness, while DCE may not be necessary for the concordant group. The VI-RADS scoring system performed with overall good diagnostic performance in evaluating muscle-invasiveness in BCa patients.4 TECHNICAL EFFICACY: Stage 3.© 2022 International Society for Magnetic Resonance in Medicine.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2020]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei,China.
通讯作者:
通讯机构: [1]Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei,China. [*1]Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,1095# Jiefang Avenue Wuhan 430030,Hubei,China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题