Prospective comparison of integrated on-site CT-fractional flow reserve and static CT perfusion with coronary CT angiography for detection of flow-limiting coronary stenosis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China [2]Canon Med Syst Corp, Otawara, Japan [3]Canon Med China, Beijing, Peoples R China [4]Huazhong Univ Sci & Technol, Dept Radiol, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China [5]Fudan Univ, Zhongshan Hosp, Dept Nucl Med, Shanghai, Peoples R China [6]Fudan Univ, Zhongshan Hosp, Dept Cardiol, Shanghai, Peoples R China
出处:
ISSN:

关键词: Coronary artery disease Multidetector computed tomography Coronary angiography Myocardial perfusion imaging Fractional flow reserve myocardial

摘要:
Objectives To compare the diagnostic power of separately integrating on-site computed tomography (CT)-derived fractional flow reserve (CT-FFR) and static CT stress myocardial perfusion (CTP) with coronary computed tomography angiography (CCTA) in detecting patients with flow-limiting CAD. The flow-limiting stenosis was defined as obstructive (>= 50%) stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Methods Forty-eight patients (74 vessels) were enrolled who underwent research-indicated combined CTA-CTP (320-row CT scanner, temporal resolution 137 ms) and SPECT/MPI prior to conventional coronary angiography. CT-FFR was computed on-site using resting CCTA data with dedicated workstation-based software. All five imaging modalities were analyzed in blinded independent core laboratories. Logistic regression and the integrated discrimination improvement (IDI) index were used to evaluate incremental differences in CT-FFR or CTP compared with CCTA alone. Results The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI was 40%. Per-vessel sensitivity and specificity were 95 and 42% for CCTA, 76 and 89% for CCTA + CTP, and 81 and 96% for CCTA + CT-FFR, respectively. The diagnostic performance of CCTA (AUC = 0.82) was improved by combining it with CT-FFR (AUC = 0.92, p = 0.01; IDI = 0.27, p < 0.001) or CTP (AUC = 0.90, p = 0.02; IDI = 0.18, p = 0.003). Conclusion On-site CT-FFR combined with CCTA provides an incremental diagnostic improvement over CCTA alone in identifying patients with flow-limiting CAD defined by ICA + SPECT/MPI, with a comparable diagnostic accuracy for integrated CTP and CCTA.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2019]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China