Diagnostic Accuracy of T-SPOT.TB Assay for Tuberculous Meningitis: An Updated Meta-Analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Lab Med,Tongji Med Coll,Wuhan,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Clin Immunol,Tongji Med Coll,Wuhan,Peoples R China [3]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Dermatol,Wuhan,Peoples R China
出处:
ISSN:

关键词: tuberculous meningitis T-SPOT TB peripheral blood cerebrospinal fluid diagnosis meta-analysis

摘要:
Background:The role of T-SPOT.TB (T-SPOT) assay for tuberculous meningitis (TBM) diagnosis has not been fully assessed. Here, we conducted an updated meta-analysis to evaluate the diagnostic accuracy of peripheral blood (PB) T-SPOT and cerebrospinal fluid (CSF) T-SPOT for diagnosing TBM. Methods:Relevant studies in the PubMed database, EmBase database, Cochrane database, Scopus database, Google Scholar, China National Knowledge Internet, and Wan-Fang database were retrieved from August 1, 2005, to June 22, 2020. Statistical analysis was performed using Stata, Revman, and Meta-Disc software. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver operating characteristic curves, and the area under the curve were determined and analyzed. Results:A total of 27 studies were eligible for inclusion within the meta-analysis. The pooled sensitivity and specificity of PB T-SPOT for TBM diagnosis were 0.78 (95% CI, 0.76-0.81) and 0.68 (95% CI, 0.66-0.71), respectively, whereas the pooled PLR, NLR, and DOR were 2.80 (95% CI, 2.29-3.42), 0.32 (95% CI, 0.27-0.38), and 10.08 (95% CI, 7.21-14.08), respectively. On the other hand, the pooled sensitivity and specificity of CSF T-SPOT on diagnosing TBM were 0.76 (95% CI, 0.72-0.80) and 0.88 (95% CI, 0.85-0.90), respectively, whereas the pooled PLR, NLR, and DOR were 5.92 (95% CI, 4.25-8.25), 0.28 (95% CI, 0.21-0.39), and 29.05 (95% CI, 16.40-51.45), respectively. The area under the summary receiver operating characteristic curve values of PB T-SPOT and CSF T-SPOT for TBM diagnosis were 0.83 (95% CI, 0.80-0.86) and 0.92 (95% CI, 0.89-0.94), respectively. Conclusions:CSF T-SPOT showed a higher specificity compared with PB T-SPOT for diagnosing TBM. Both two T-SPOT assays have considerable potential in improving the diagnosis of TBM. Furthermore, the standardization of the operating procedure is further needed when performing CSF T-SPOT.

基金:

基金编号: 2017ZX10103005-007 81401639

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 神经科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 神经科学
JCR分区:
出版当年[2018]版:
Q3 CLINICAL NEUROLOGY Q3 NEUROSCIENCES
最新[2023]版:
Q2 CLINICAL NEUROLOGY Q3 NEUROSCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Lab Med,Tongji Med Coll,Wuhan,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)