SEMAC-VAT and MSVAT-SPACE Sequence Strategies for Metal Artifact Reduction in 1.5T Magnetic Resonance Imaging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Peoples R China [2]Siemens AG, Healthcare Sect, Malvern, PA USA [3]Univ Texas Med Branch, Dept Radiol, Galveston, TX USA [4]Siemens AG, Healthcare Sect, Erlangen, Germany [5]Univ Texas Med Branch, Dept Orthopaed Surg & Rehabil, Galveston, TX USA
出处:
ISSN:

关键词: magnetic resonance imaging metal artifact reduction view angle tilting orthopedic implants SEMAC VAT MSVAT-SPACE SEMAC-VAT titanium stainless steel

摘要:
Objectives: To evaluate the ability of four magnetic resonance imaging (MRI) techniques to correct for metallic artifacts. These techniques consisted of 3 2D techniques and one 3D technique. In 2D imaging the techniques View Angle Tilting (VAT), Slice Encoding for Metal Artifact Correction (SEMAC) and a technique that employed a combination of the first two (SEMAC-VAT) were evaluated. In 3D imaging the technique Multiple Slab acquisition with VAT based on a SPACE sequence was evaluated (MSVAT-SPACE). Materials and Methods: Agarose phantoms and tissue phantoms with two commonly used metal implants (stainless steel and titanium) as well as two volunteers with metal implants were imaged at 1.5T. All phantoms and volunteers were imaged using VAT, SEMAC, SEMAC-VAT and MSVAT-SPACE techniques, as well as 2D and 3D conventional imaging techniques. Each technique was optimized for different image contrast mechanisms. Artifact reduction was quantitatively assessed in the agarose phantoms by volumetric measurement. Image quality was qualitatively assessed by blinded reads employing two readers. Each reader independently viewed the tissue phantom images and in vivo human images. Statistical analysis was performed using a Friedman test, Wilcoxon test and weighted Cohen's kappa test. Results: T1-weighted, T2-weighted, PD-weighted and STIR image contrasts were successfully implemented with the evaluated artifact reduction sequences in both the phantom experiments and in vivo images. For all evaluated image contrasts and both metal implants, a reduction in the volume of metal artifacts was seen when compared with 2D conventional acquisitions. The 2D metal artifact volumes on average were reduced by 49% +/- 16%, 56% +/- 15% and 63% +/- 15% for VAT, SEMAC and SEMAC-VAT acquisitions respectively. When Friedman and Wilcoxon tests were applied the difference in metal artifact volume was found to be statistically significant when VAT, SEMAC and SEMAC-VAT were compared with the 2D conventional techniques. In 3D imaging on average MSVAT-SPACE reduced metal artifact volume compared with the 3D conventional imaging technique by 72% +/- 23% for all evaluated image contrasts and both metal implants. The metal artifact volume differences were statistically significant when MSVAT-SPACE was compared with the 3D conventional technique. The blinded reads demonstrated that SEMAC-VAT and MSVAT-SPACE had distinctly superior quality compared with conventional acquisitions. Quality was measured in terms of artifact size, distortions, image quality and visualization of bone marrow and soft tissues adjacent to metal implants. This was the case for both tissue phantom images and human images with good interobserver agreement. Conclusions: SEMAC-VAT (2D) and MSVAT-SPACE (3D) demonstrated a consistent, marked reduction of metal artifacts for different metal implants and offered flexible image contrasts (T1, T2, PD and STIR) with high image quality. These techniques likely will improve the evaluation of postoperative patients with metal implants.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 2 区 医学
小类 | 1 区 核医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2010]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, 1095 JieFang Ave, Wuhan 430030, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)