高级检索
当前位置: 首页 > 详情页

Multicontrast Single-Slab 3D MRI to Detect Cerebral Metastasis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China
出处:
ISSN:

关键词: cerebral metastasis MRI oncologic imaging

摘要:
OBJECTIVE. The purpose of this study was to evaluate the sensitivities and specificities of four single-slab 3D MRI sequences in the detection of cranial metastases: double inversion recovery (IR), T2 FLAIR, contrast-enhanced T2 FLAIR, and contrast-enhanced IR-prepared fast spoiled gradient-echo (FSPGR) sequences. SUBJECTS AND METHODS. Eighty-four patients underwent double IR and T2 FLAIR imaging using 3-T MRI. Then, 49 of 84 patients were randomly selected to undergo contrast-enhanced IR-prepared FSPGR before contrast-enhanced T2 FLAIR, and the other 35 patients underwent contrast-enhanced T2 FLAIR before contrast-enhanced IR-prepared FSPGR. Two experienced neuroradiologists reviewed the images by consensus on a workstation. Metastases were scored a negative, equivocal, or positive. For each metastasis, we recorded the anatomic area and size, and checked whether edema was present. RESULTS. A total of 210 cranial metastases in 56 of 84 patients were revealed. The sensitivities of double IR, T2 FLAIR, contrast-enhanced IR-prepared FSPGR, and contrast-enhanced T2 FLAIR sequences were 66.2%, 56.7%, 80.5%, and 99%, respectively. The specificities were 68.3%, 73%, 75.7%, and 82.4%. The areas under the receiver operating characteristic curve were 0.763, 0.709, 0.865, and 0.993. Contrast-enhanced T2 FLAIR imaging was found to have the highest sensitivity especially for detecting lesions in meninges (98.2%; p < 0.0001) and gray matter (GM) (100%; p < 0.0001). The double IR sequence was superior to the T2 FLAIR sequence for imaging metastases located in ependyma (81.8% vs 36.4%) and GM (66.7% vs 48.1%). Delayed enhancement did not affect the sensitivities of the contrast-enhanced T2 FLAIR and contrast-enhanced IR-prepared FSPGR sequences. CONCLUSION. Contrast-enhanced T2 FLAIR is the most sensitive sequence of the four MR sequences evaluated for the detection of cranial metastases despite its delay time after contrast enhancement.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2010]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Ave, Wuhan 430030, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Ave, Wuhan 430030, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)