高级检索
当前位置: 首页 > 详情页

Depiction of Transplant Renal Vascular Anatomy and Complications: Unenhanced MR Angiography by Using Spatial Labeling with Multiple Inversion Pulses

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 自然指数

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Infect, Wuhan 430030, Hubei, Peoples R China
出处:
ISSN:

摘要:
Purpose: To evaluate the ability to depict anatomy and complications of renal vascular transplant with unenhanced magnetic resonance (MR) angiography with spatial labeling with multiple inversion pulses (SLEEK) and to compare the results with color Doppler (CD) ultrasonography (US), digital subtraction angiography (DSA), and intraoperative findings. Materials and Methods: This study was approved by the institutional review board, and written informed consent was received before examination. Seventy-five patients who underwent renal transplantation were examined with unenhanced MR angiography with SLEEK and CD US. DSA was performed in 15 patients. Surgery was performed in eight patients. The ability of SLEEK to show transplant renal vascular anatomy and complications was evaluated by two experienced radiologists who compared the results with CD US, DSA, and intraoperative findings. Results: Patients successfully underwent SLEEK MR angiography. Transplant renal vascular anatomy was assessed in 87 arteries and 78 veins. Renal vascular complications from transplantation were diagnosed in 23 patients, which included 14 with arterial stenosis, three with arterial kinking, two with arteriovenous fistulas, two with venous stenosis, one with pseudoaneurysms, and one with fibromuscular dysplasia. Three patients had two renal transplants and nine patients had nine accessory renal arteries. More accessory renal arteries were detected with SLEEK than with CD US. Correlation was excellent between the stenosis degree with SLEEK and DSA (r = 0.96; P < .05). For those with significant artery stenosis (>50% narrowing) proved with DSA (n = 7) or surgery (n = 3), positive predictive value was 91% (10 of 11). Conclusion: Unenhanced MR angiography with SLEEK preliminarily proved to be a reliable diagnostic method for depiction of anatomy and complications of renal vascular transplant. It may be used for evaluation of patients with renal transplant, and in particular for those with renal insufficiency.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 2 区 医学
小类 | 1 区 核医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2012]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)