高级检索
当前位置: 首页 > 详情页

The diagnostic value of non-contrast enhanced quiescent interval single shot (QISS) magnetic resonance angiography at 3T for lower extremity peripheral arterial disease, in comparison to CT angiography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Vasc Surg, Wuhan, Hubei, Peoples R China [3]Siemens Healthineers, Northeast Asia Collaborat, Beijing, Peoples R China [4]St Johns Hosp, Tulsa, OK USA [5]Siemens Healthcare, Cardiovasc MR R&D, Chicago, IL USA [6]SIEMENS Healthcare, MR Sci, Shanghai, Peoples R China
出处:
ISSN:

关键词: Non-contrast enhanced Magnetic resonance angiography Lower extremity Peripheral arterial disease

摘要:
Background: The high incidence of renal insufficiency in patients with Peripheral Arterial Disease raises the concern for nephrogenic systemic fibrosis (NSF) with respect to contrast enhanced MRA. The risk of NSF is eliminated with non-contrast enhanced magnetic resonance angiography. The purpose of the current study is to compare image quality and diagnostic performance of non-contrast enhanced Quiescent Interval Single Shot (QISS) magnetic resonance angiography at 3T versus CT angiography for evaluation of lower extremity Peripheral Arterial Disease (PAD). Methods: 32 consecutive patients (23 male, 9 female, age range 40-81 years, average age 61.97 years) with clinically suspected lower extremity PAD underwent QISS MRA and CTA. 19 of 32 patients underwent Digital Subtraction Angiography (DSA). Image quality of MRA was compared with CTA by two radiologists with 10 and 8 years' experience according to a 4-point scale. The Kappa test was used to determine the intermodality agreement between MRA and CTA in stenosis assessment, and interobserver agreement with each method. Sensitivity and specificity of CTA and MRA in detecting hemodynamically significant stenosis (>= 50 %) were compared, with DSA serving as reference standard when available. Results: Image quality of QISS MRA was rated 3.70 +/- 0.49 by reader 1, and 3.72 +/- 0.47 by reader 2, significantly lower than that of CTA (3.80 +/- 0.44 and 3.82 +/- 0.42, P < 0.001 for both readers). Intermodality agreement between MRA and CTA was excellent for assessment of stenosis (Kappa = 0.923 +/- 0.013 for reader 1, 0.930 +/- 0.012 for reader 2). Interobserver agreement was 0.936 +/- 0.012 for CTA and 0.935 +/- 0.011 for MRA. For readers 1 and 2 respectively, the sensitivity of QISS was 94.25 and 93.26 % (versus 90.11 and 89.13 % for CTA, P > 0.05), and specificity of QISS was 96.70 and 97.75 % (versus 96.55 and 96.51 % for CTA, P > 0.05). For heavily calcified segments, sensitivity of QISS (95.83 and 95.83 %) was significantly higher than that of CTA (74.19 and 76.67 %, P < 0.05). Conclusion: QISS is a reliable alternative to CTA for evaluation of lower extremity PAD, and may be suitable as a first-line screening examination in patients with contraindications to intravenous contrast administration.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 2 区 医学
小类 | 2 区 心脏和心血管系统 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 心脏和心血管系统 2 区 核医学
JCR分区:
出版当年[2014]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)