Study of the disparity of noninvasive and invasive blood pressure measured by the Philips Intellivue MP50 monitor in surgeries inducing gall cardiac reflex under general anesthesia
Objective The aim of the present study was to comprehensively compare noninvasive and invasive blood pressure (BP) measured by the Philips Intellivue MP50 monitor in surgeries that may induce gall cardiac reflex under general anesthesia. Participants and methods Seventy-eight patients undergoing cholecyst or bile duct operations under general anesthesia were enrolled in our study. Both invasive (intraradial, femoral, or dorsalis pedis artery) and noninvasive (oscillometric) BP were monitored by the Philips Intellivue MP50 monitor simultaneously. Data were analyzed using Bland-Altman plots. Results In a supine position during operations, between intraradial and oscillometric measurements, the bias and precision (mmHg) were 9.34 +/- 12.98 and 12.47 +/- 10.00 for systolic blood pressure (SBP) and 3.26 +/- 8.22 and 6.53 +/- 5.97 for diastolic blood pressure (DBP), between intrafemoral and oscillometric measurements, the bias and precision (mmHg) were 14.40 +/- 14.38 and 16.93 +/- 11.28 for SBP and 4.35 +/- 9.72 and 7.52 +/- 7.54 for DBP, between intradorsalis pedis and oscillometric measurements, the bias and precision (mmHg) were 15.69 +/- 14.37 and 16.91 +/- 12.91 for SBP and 0.99 +/- 7.69 and 5.67 +/- 5.27 for DBP. Conclusion The oscillometric BP showed poor agreement with intra-arterial BP in cholecyst or bile duct surgeries that may induce gall cardiac reflex under general anesthesia. Therefore, according to the present data, application of oscillometric BP measured by the Philips Intellivue MP50 monitor in these surgery patients under general anesthesia cannot be recommended generally. Copyright (c) 2018 Wolters Kluwer Health, Inc. All rights reserved.
第一作者单位:[1]Nanjing Med Univ, Affiliated Hosp 1, Dept Urol, Nanjing, Nanjing Provinc, Peoples R China[3]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Urol,Wuhan 430030,Hubei,Peoples R China
通讯作者:
通讯机构:[1]Nanjing Med Univ, Affiliated Hosp 1, Dept Urol, Nanjing, Nanjing Provinc, Peoples R China[*1]Nanjing Med Univ, Affiliated Hosp 1, Dept Urol, Nanjing 210029, Jiangsu, Peoples R China
推荐引用方式(GB/T 7714):
Meng Xianghu,Zang Guanghui,Li Rui,et al.Study of the disparity of noninvasive and invasive blood pressure measured by the Philips Intellivue MP50 monitor in surgeries inducing gall cardiac reflex under general anesthesia[J].BLOOD PRESSURE MONITORING.2018,23(1):19-23.doi:10.1097/MBP.0000000000000304.
APA:
Meng, Xianghu,Zang, Guanghui,Li, Rui,Fan, Longchang,Liu, Jihong&Wang, Zengjun.(2018).Study of the disparity of noninvasive and invasive blood pressure measured by the Philips Intellivue MP50 monitor in surgeries inducing gall cardiac reflex under general anesthesia.BLOOD PRESSURE MONITORING,23,(1)
MLA:
Meng, Xianghu,et al."Study of the disparity of noninvasive and invasive blood pressure measured by the Philips Intellivue MP50 monitor in surgeries inducing gall cardiac reflex under general anesthesia".BLOOD PRESSURE MONITORING 23..1(2018):19-23