高级检索
当前位置: 首页 > 详情页

The "safe zone" for infrapectineal plate-screw fixation of quadrilateral plate fractures An anatomical study and retrospective clinical evaluation

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Traumat Surg, Jie Fang Ave 1095, Wuhan, Hubei, Peoples R China [2]Jiujiang Univ, Clin Med Coll, Jiujiang Univ Hosp, Dept Orthopaed Surg, Xun Yang East Rd 57, Jiujiang, Peoples R China [3]Hebei Med Univ, Hosp 3, Dept Orthopaed Surg, Zi Qiang Ave 139, Shijiazhuang, Hebei, Peoples R China
出处:
ISSN:

关键词: infrapectineal plate-screw fixation quadrilateral plate fracture safe zone two-ended fixation

摘要:
Extra-articular screw placement in the true pelvis for fixing quadrilateral plate fractures remains challenging. We aimed to define the "safe zone" on the quadrilateral surface to facilitate safe plate-screw placement. Twenty cadaveric hemipelves were sectioned and assembled to define the projection of the acetabular boundary on the quadrilateral surface. Three lines (X, Y, and Z) were drawn tangent to the projection, with X parallel to the iliopectineal line, Y perpendicular to the iliopectineal line, and Z parallel to the posterior border of the ischial body. Then, the distances between X and the iliopectineal line (D1), Y and the sacroiliac joint (D2), and Z and the posterior border of the ischium (D3) could be used to determine a "safe zone" on the quadrilateral surface for screw insertion. We included 15 patients whose conditions satisfied the definition of a comminuted quadrilateral plate fracture and applied two-ended buttress plates for treatment in accordance with this "safe zone." The average D1 was 50.0mm, the average D2 was 30.6mm, and the average D3 was 12.4mm. For all 15 patients with comminuted quadrilateral fracture who were treated, no intraoperative or postoperative screw penetration of the acetabulum was identified, and no loss of reduction was observed during an average follow up of 17.7 months. The "safe zone" established in this study simplifies extraarticular screw placement for managing quadrilateral plate fractures in the true pelvis. As a result, two-ended buttress plate fixation in the true pelvis becomes safe, therefore, treatment with two-ended buttress plates may represent a viable alternative to single-ended elastic fixation in the management of comminuted quadrilateral fractures.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 3 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2017]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2024]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2024版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Traumat Surg, Jie Fang Ave 1095, Wuhan, Hubei, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Traumat Surg, Jie Fang Ave 1095, Wuhan, Hubei, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Wuhan, Hubei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)