高级检索
当前位置: 首页 > 详情页

Value of contrast-enhanced ultrasound for preoperative assessment of liver reserve function in patients with liver tumors

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, Wuhan, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Pediat, Wuhan, Hubei, Peoples R China [3]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Hepat Surg, Wuhan, Hubei, Peoples R China
出处:
ISSN:

摘要:
This study aimed to investigate the value of contrast-enhanced ultrasound (CEUS) for pre-operative assessment of liver reserve function in patients with liver tumors. The indocyanine green (ICG) clearance tests and CEUS examinations of 45 noncirrhotic patients with liver tumors were performed prior to liver resection. Parameters time to peak (TtoPk), arrival time (Atm) as well as perfusion parameters A, k and A x k were generated from time-intensity curve (TIC) of CEUS. The correlation analyses of the ICG clearance per unit time (ICGK) and the retention rate at 15 min (ICGR15) with TtoPk, Atm, A, k and A x k were performed, and the diagnostic ability as well as optimal cut-off values of TtoPk and Atm for differentiating patients with ICGR15>10% from ICGR15<10% were analyzed. There were significant correlations of ICGK with TtoPk and Atm, and the correlation coefficients were 0.363 (p = 0.014) and -0.482 (p = 0.001), respectively. Significant correlations of ICGR15 with TtoPk and Atm were revealed, and the correlation coefficients were -0.416 (p = 0.004) and 0.303 (p = 0.043), respectively. No correlation of ICGK or ICGR15 with A, k and A x k was found in this study. There were significant differences in TtoPk and Atm between patients with ICGR15>10% and ICGR15<10% (p = 0.028 and p = 0.026, respectively). TtoPk and Atm both had good diagnostic abilities in diagnosing patients with ICGR15>10% verusus ICGR15<10% (AUROC = 0.711 and 0.721, respectively). For ICGR15>10% vs ICGR15, the optimal cut-off values of TtoPk and Atm were 13.307 s and 11.007 s, respectively, while the sensitivity and specificity were 75.0% and 72.7%, 60.6% and 75.0%, respectively. This study revealed that CEUS has the potential to be a new method to evaluate the liver reserve function of patients. With the optimal cut-off values of TtoPk and Atm, qualitative assessment of patients with ICGR15> 10% could be more easily achieved by CEUS with good diagnostic abilities.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2017]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, Wuhan, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)