高级检索
当前位置: 首页 > 详情页

Examination of the Effect of a 50-Hz Electromagnetic Field at 500 μT on Parameters Related With the Cardiovascular System in Rats

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ SSCI

单位: [1]Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China [2]China Elect Power Res Inst, High Voltage Res Inst, State Key Lab Power Grid Environm Protect, Wuhan, Peoples R China [3]Huazhong Univ Sci & Technol, Div Cardiol, Wuhan, Peoples R China [4]Huazhong Univ Sci & Technol, Hubei Key Lab Genet & Mol Mech Cardiol Disorders, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
出处:
ISSN:

关键词: electromagnetic field cardiovascular system physiology cardiac remodeling rat

摘要:
Background: Whether electromagnetic field (EMF) exposure affects the function of the cardiovascular system is under debate. The present study aimed to investigate the effects of 500 mu T EMF exposure on the cardiovascular system in rats. Methods: Forty-eight-week-old male Sprague-Dawley rats were randomly divided into two groups: the sham group and the exposure group. During 24-week EMF exposure (20 h per day), the blood pressure and pulse rate were recorded every 4 weeks. Before sacrifice, electrocardiography, echocardiography, and cardiac catheterization analysis were conducted to evaluate the cardiac function. Meanwhile, hematoxylin-eosin (HE) staining, Western blot, and real-time polymerase chain reaction (PCR) were performed to identify morphological and molecular changes indicative of cardiac remodeling. Results: The heart rate, blood pressure, and pulse rate were not influenced by EMF exposure compared with the control group. In addition, HE staining showed no change in the morphology and arrangement of cardiomyocytes. Further, we found that the mRNA and protein levels of cardiac hypertrophy-related genes were not affected by EMF exposure. Finally, no significant difference was observed in cardiac function between the two groups by echocardiography and cardiac catheterization detection. Conclusion: The 24-week exposure to EMF at 500 mu T did not have apparent effects on the cardiovascular system in rats, at least for the variables studied.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 3 区 公共卫生、环境卫生与职业卫生
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 公共卫生、环境卫生与职业卫生
JCR分区:
出版当年[2018]版:
Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
最新[2024]版:
Q1 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China [2]China Elect Power Res Inst, High Voltage Res Inst, State Key Lab Power Grid Environm Protect, Wuhan, Peoples R China
通讯作者:
通讯机构: [3]Huazhong Univ Sci & Technol, Div Cardiol, Wuhan, Peoples R China [4]Huazhong Univ Sci & Technol, Hubei Key Lab Genet & Mol Mech Cardiol Disorders, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:630 今日访问量:0 总访问量:457 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)