高级检索
当前位置: 首页 > 详情页

Cardiac magnetic resonance imaging detection of intramyocardial hemorrhage in patients with ST-elevated myocardial infarction: comparison between susceptibility-weighted imaging and T1/T2 mapping techniques

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Internal Med, Div Cardiol,Hubei Key Lab Genet & Mol Mech Cardiol, Wuhan, Peoples R China [3]Bayer Healthcare, Shanghai, Peoples R China [4]Siemens Healthineers Ltd, MR Collaborat, Shanghai, Peoples R China
出处:
ISSN:

关键词: Susceptibility-weighted imaging (SWI) T1 mapping T2 mapping intramyocardial hemorrhage (IMH) cardiac magnetic resonance (CMR)

摘要:
Background: Susceptibility-weighted imaging (SWI) and T1/T2 mapping can be used to detect reperfusion intramyocardial hemorrhage (IMH) in ST-segment elevation myocardial infarction (STEMI) patients. However, the sensitivity and accuracy of the SWI and T1/T2 mapping sequences were not systematically compared. The study aimed to evaluate image quality and diagnostic performance of SWI in patients with IMH, compared with T1/T2 mapping. Methods: A prospective study was conducted on consecutive acute STEMI patients who were recruited from January to July 2022. Within 2-6 days after reperfusion treatment, all patients underwent a 3T cardiac magnetic resonance (CMR) examination, including T2-weighted short-tau inversion recovery (T2W-STIR), T1/T2 mapping, and SWI. A total of 36 patients [age, 56.50 +/- 17.25 years; males, 83.33% (30/36)] were enrolled. The relative infarct-remote myocardium signal intensity ratio (SIinfarct-remote) and contrast to-noise ratio (CNR) were calculated for each patient on T1/T2 mapping and SWI, and the difference between relative signal intensity-to-noise ratio (rSNR) in the IMH (rSNRIMH) was measured for IMH patients on T1/T2 mapping and SWI. SIinfarct-remote, CNR, and rSNRIMH were compared among the three sequences. Receiver operating characteristic (ROC) analyses were used to evaluate the diagnostic performance of three sequences by SIinfarct-remote and visual assessment. Results: A total of 26 (72.22%) patients had IMH. Quantitatively, the SIinfarct-remote of three sequences had excellent diagnostic performance for detecting IMH [SWI area under the curve (AUC) =1.000, 95% confidence interval (CI): 1.000-1.000 vs. T1 mapping AUC =0.954, 95% CI: 0.885-1.000 vs. T2 mapping AUC =0.985, 95% CI: 0.955-1.000; SWI vs. T1 mapping, P=0.300; SWI vs. T2 mapping, P=0.188; T1 mapping vs. T2 mapping, P=0.302). Qualitatively, three sequences had similar performance on detecting IMH (SWI AUC =0.895, 95% CI: 0.784-1.000; T1 mapping AUC =0.835, 95% CI: 0.711-0.958; and T2 mapping AUC =0.855, 95% CI: 0.735-0.974; SWI vs. T1 mapping, P=0.172; SWI vs. T2 mapping, P=0.317; T1 mapping vs. T2 mapping, P=0.710). The rSNRIMH was highest in T1 mapping, followed by T2 mapping and SWI, but SWI had the highest CNR. Conclusions: SWI, as well as T1/T2 mapping, is a feasible and accurate approach for clinical diagnosis of IMH with excellent performance.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2021]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:419 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)