Dark blood T2-weighted imaging of the human heart with AI-assisted compressed sensing: a patient cohort study

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China [2]Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen, China [3]United Imaging Healthcare, Shanghai, China [4]UIH America, Inc., Houston, TX, USA
出处:
ISSN:

关键词: Artificial intelligence (AI) compressed sensing T2-weighted imaging dark blood MRI

摘要:
Dark blood T2-weighted (DB-T2W) imaging is widely used to evaluate myocardial edema in myocarditis and inflammatory cardiomyopathy. However, this technique is sensitive to arrhythmia, tachycardia, and cardiac and respiratory motion due to the long scan time with multiple breath-holds. The application of artificial intelligence (AI)-assisted compressed sensing (ACS) has facilitated significant progress in accelerating medical imaging. However, the effect of DB-T2W imaging on ACS has not been elucidated. This study aimed to examine the effects of ACS on the image quality of single-shot and multi-shot DB-T2W imaging of edema.Thirty-three patients were included in this study and received DB-T2W imaging with ACS, including single-shot acquisition (SS-ACS) and multi-shot acquisition (MS-ACS). The resulting images were compared with those of the conventional multi-shot DB-T2W imaging with parallel imaging (MS-PI). Quantitative assessments of the signal-to-noise ratio (SNR), tissue contrast ratio (CR), and contrast-to-noise ratio (CNR) were performed. Three radiologists independently evaluated the overall image quality, blood nulling, free wall of the left ventricle, free wall of the right ventricle, and interventricular septum using a 5-point Likert scale.The total scan time of the DB-T2W imaging with ACS was significantly reduced compared to the conventional parallel imaging [number of heartbeats (SS-ACS:MS-ACS:MS-PI) =19:63:99; P<0.001]. The SNRmyocardium and CNRblood-myocardium of MS-ACS and SS-ACS were higher than those of MS-PI (all P values <0.01). Furthermore, the CRblood-myocardium of SS-ACS was also higher than that of MS-PI (P<0.01). There were significant differences in overall image quality, blood nulling, left ventricle free wall visibility, and septum visibility between the MS-PI, MS-ACS, and SS-ACS protocols (all P values <0.05). Moreover, blood in the heart was better nulled using SS-ACS (P<0.01).The ACS method shortens the scan time of DB-T2W imaging and achieves comparable or even better image quality compared to the PI method. Moreover, DB-T2W imaging using the ACS method can reduce the number of breath-holds to 1 with single-shot acquisition.2023 Quantitative Imaging in Medicine and Surgery. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2021]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China [*1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)