高级检索
当前位置: 首页 > 详情页

Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology,Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology,Wuhan 430030, Hubei Province, China [2]St. John’s Medical Center, Tulsa, OK 74133, United States
出处:
ISSN:

关键词: Magnetic resonance imaging Diffusion-weighted imaging Crohn's disease Ileum Reproducibility

摘要:
BACKGROUND Magnetic resonance enterography (MRE) is increasingly attractive as a noninvasive and radiation-free tool for assessing Crohn's disease (CD). Diffusion weighted imaging (DWI) is recommended as an optional MRE sequence for CD by the European Society of Gastrointestinal and Abdominal Radiology, and has shown a superb potential as a quantitative modality for bowel inflammation evaluation. However, the measurement reproducibility of quantitative DWI analysis in MRE has not been ascertained so far. To facilitate the application of quantitative diffusion-weighted MRE in the clinical routine, systematic investigations of the intra and interobserver reproducibility of DWI quantitative parameters should be performed. AIM To evaluate the intra and interobserver reproducibility of quantitative analysis for diffusion-weighted MRE (DW-MRE) in ileal CD. METHODS Forty-four subjects (21 with CD and 23 control subjects) who underwent ileocolonoscopy and DW-MRE (b = 800 s/mm(2)) within one week were included. Two radiologists independently measured apparent diffusion coefficients (ADC) of the terminal ileum and signal intensity ratio (SR) of the terminal ileum to ipsilateral psoas muscle on DWI images (b = 800 s/mm(2)). Between-and with in reader agreements were assessed using intraclass correlation coefficients (ICC), coefficients of variation (CoV), and 95% limits of agreement of Bland-Altman plots (BA-LA LoA). Diagnostic performances of ADC and SR for identifying inflamed terminal ileum from the normal were evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS There were no significant differences in ADC or SR values between the two sessions or between the two radiologists either in the CD or control group (paired t-test, P > 0.05). The intra and interobserver reproducibility of ADC (ICC: 0.952-0.984; CoV: 3.73-6.28%; BA-LA LoA: +/- 11.27% to +/- 15.88%) and SR (ICC: 0.969-0.989; CoV: 3.51%-4.64%; BA-LA LoA: +/- 10.62% to +/- 15.45%) was excellent for CD. Agreement of ADC measurements was slightly less in control subjects (ICC: 0.641-0.736; CoV: 10.47%-11.43%; BA-LA LoA: +/- 26.59% to +/- 30.83%). SR of normal terminal ileum demonstrated high intra and interobserver reproducibility (ICC: 0.944-0.974; CoV: 3.73%-6.28%; BA-LA LoA: +/- 18.58% to +/- 24.43%). ADC and SR of two readers had outstanding diagnostic efficiencies (area under the ROC curve: 0.923-0.988). CONCLUSION Quantitative parameters derived from DW-MRE have good to excellent intra and interobserver agreements with high diagnostic accuracy, and can serve as robust and efficient quantitative biomarkers for CD evaluation.

基金:

基金编号: 81571642 81701657 81771801 2017KFYXJJ126

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 医学
小类 | 3 区 胃肠肝病学
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 胃肠肝病学
JCR分区:
出版当年[2017]版:
Q2 GASTROENTEROLOGY & HEPATOLOGY
最新[2024]版:
Q1 GASTROENTEROLOGY & HEPATOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Department of Radiology,Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology,Wuhan 430030, Hubei Province, China
通讯作者:
通讯机构: [1]Department of Radiology,Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology,Wuhan 430030, Hubei Province, China [*1]Department of Radiology,Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology,1095 Jiefang Avenue, Wuhan 430030, Hubei Province, China
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

资源点击量:622 今日访问量:0 总访问量:452 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)